Skip to main content

Hematological reference intervals for Danish crossbred Landrace Yorkshire Duroc (LYD) pigs used in biomedical research

Abstract

Background

The health and welfare of pigs used in biomedical research is essential to research quality and compliance with the 3Rs (replacement, reduction, and refinement). Hematological variables are objective markers to quantitatively determine health issues and evaluate physiological differences before and after experimental procedures. There are no recent validated hematologic reference intervals (RIs) published for Danish crossbred Landrace Yorkshire Duroc (LYD) pigs to aid researchers and veterinarians in their decision-making. The objective of this study was to establish hematologic RIs for LYD pigs used for biomedical research. Blood samples were collected from healthy female LYD pigs (35–65 kg) and analyzed using the in-house ProCyte Dx Hematology Analyzer. Means with 90% confidence intervals for lower and upper limits were calculated according to guidelines by the American Society of Veterinary Clinical Pathology.

Results

Inspection of 141 pigs led to 133 blood samples available for analyses after exclusions due to clinical signs of disease, inadequate tube filling or presence of macroscopic clots. Thirty-two samples reported platelet abnormalities and upon further investigation these samples were excluded when calculating RIs for platelets and platelet indices. Other measurements were not affected. The RI for red blood cells, hemoglobin, hematocrit and white blood cells were 5.10–7.00 × 106/µL, 9.36–12.29 g/dL, 30.46–40.47%, and 11.73–25.00 × 103/µL, respectively.

Conclusions

Our study provides RIs for hematological variables in LYD pigs, revealing significant differences from published RIs of other breeds. These findings highlight the influence of factors like age, breed and health status on measurements, emphasizing the importance of using breed-specific RIs. This research supports the 3Rs, guiding better animal care and enhancing overall research quality.

Background

The pig is extensively used in biomedical research and for surgical training purposes due to the comparative nature of its organs [1]. In the European Union and Norway, approximately 73,500 pigs were utilized for scientific purposes in 2020, with global figures estimated to be significantly higher [2].

Ensuring the health and welfare of laboratory pigs is essential not only for the quality and consistency of research outcomes but also to adhere to the principles of the 3Rs—replacement, reduction, and refinement—governing the ethical use of animals in research [3, 4]. Clinical laboratories play an indispensable role in this context, providing objective data that assist in the evaluation, monitoring, and decision-making processes of an animal’s fate. Reliable and accurate RIs for laboratory analyses are crucial to quantitatively and unbiased identify health issues, make informed decisions on the inclusion or exclusion of animals, and assess physiological changes before and after experimental procedures, [5, 6]. These RIs support the 3Rs by facilitating reduction—using the fewest animals necessary—and refinement—minimizing or eliminating pain and distress while enhancing welfare during experiments.

In Denmark, the production of Danish crossbred LYD pigs exceeds 30 million annually, with 14 million exported and approximately 24,000 used for scientific purposes within the country [7, 8]. Despite widespread use in research, information on up-to-date hematologic RIs according to guidelines seems to be missing or appear outdated in LYD crossbred pigs. While hematologic reference values are available for miniature pigs [9,10,11,12,13] and for other breeds of domestic pigs [14,15,16,17,18,19,20,21,22,23,24,25], these can only be applied cautiously due to potential differences in breed, age, and gender [26]. To date, only one recent study describes hematologic RIs in LYD sows at mid-gestation [27]. In research, however, juvenile animals are primarily used and hematologic RIs of gestating animals is not applicable. No recent updated and validated hematologic RIs for LYD pigs are retrievable in the literature. Hence, benchmarking new RIs is warranted.

The objective of this study was to establish hematologic reference values according to established guidelines for healthy LYD pigs used for biomedical research or surgical training purposes.

Methods

This study was conducted from March 2022 until November 2022 at the Department of Clinical Medicine at Aarhus University. Blood samples were obtained from pigs used for surgical training courses approved by The Animal Experimental Council in Denmark, license number 2021-15-0201-00966. The study protocol for blood sampling followed the guidelines of the American Society of Veterinary Clinical Pathology (ASVCP), the International Federation of Clinical Chemistry (IFCC), and the Clinical and Laboratory Standards Institute (CLSI) on the de novo establishment of RIs [28,29,30,31].

Animals

All pigs (Sus scrofa domesticus) included were female gender and crossbred Landrace × Yorkshire × Duroc breed. They were retrieved from a farm that screens for seven specific pathogens as part of a national farm health-monitoring program (SPF) [32]. At day four of age, pigs received an intramuscular injection of gleptoferron combined with the anticoccidial toltrazuril for the simultaneous prevention of piglet coccidiosis and iron deficiency anemia (Forceris, CEVA Animal Health A/S, Vejle, Denmark). Pigs were additionally vaccinated for porcine circovirus (Ingelvac CircoFLEX, Boehringer Ingelheim Animal Health Nordics A/S, Copenhagen, Denmark) and for lawsonia intracellularis (Porcilis Lawsonia ID Vet., MSD Animal Health A/S, Copenhagen, Denmark). Upon arrival on the research farm, the pigs were housed in groups according to the Institution’s Animal Welfare Policy that complies with national legislation on animal experimentation. Housing has been described previously [33]. Briefly, pigs are housed indoors with photoperiods 12:12 h light:dark, and room temperature at 20 ± 4 ℃. Straw bedding is used in all pens and sprinklers are available to moist the pens if needed. Pigs are fed with a standard diet with extra fibres twice daily according to weight and have free access to water and hay.

Selection of reference pigs

The pigs were examined twice for clinical signs of disease. The day after arrival, the pigs were visually inspected by a veterinarian at rest and in locomotion. The weight of the pigs was measured, and an identification number was given to each pig. Inclusion criteria were as follows: pigs weighing between 35 and 65 kg (estimated age range 3–4 months), bright, alert, and responsive, normal skin color, body condition, and activity. Exclusion criteria were any visible health concerns such as infected skin lesions, abscesses, tail bites, diarrhea, coughing, or abnormal gait/lameness.

On days 2–6, included pigs were subjected to an additional clinical examination that comprised a visual inspection at rest and in locomotion, and a physical examination after deep sedation by intramuscular injection of a solution of 1 mL/10 kg bodyweight of Zoletil (1.56 mg/kg Zoletil 50 Vet, Virbac, Denmark) dissolved in 1.56 mg/kg ketamine (Ketaminol Vet 100 mg/mL, Intervet, Denmark), 1.56 mg/kg xylazine (Rompun Vet 20 mg/mL, Bayer, Denmark) and 2.5 mg/kg butorphanol (Torbugesic Vet 10 mg/mL, Zoetis, Denmark). Measurements of body temperature, heart rate and rhythm, respiratory frequency and lung sounds were then obtained. Pigs were excluded if any of the following were present: body temperature above 40 degrees Celsius, arrhythmia, or abnormal lung sounds. Just after the examination, blood samples for RI determination were obtained from all included pigs. The selection process is presented in Fig. 1.

Fig. 1
figure 1

Study selection process of reference pigs for reference interval determination

Blood collection and handling

A tourniquet was positioned at the base of the ear and the skin disinfected. Venipuncture was performed in the left or right marginal ear vein by use of an intravenous cannula (BD Venflon Pro, 18GA 1.1 × 32 mm, Becton Dickinson Infusion Therapy, Helsingborg, Sweden) connected to a blood tube holder (Vacuette, Holdex, Single-Use Holder PP, Greiner Bio-One, Kremsmünster, Austria). Blood samples for hematological analysis were collected into 2 mL tubes containing ethylenediamine tetraacetic acid (EDTA) (BD Vacutainer®, K2EDTA 3.6 mg, 2 mL 13 × 75 mm, Becton, Dickinson and Company, Franklin Lakes, NJ, USA). Immediately after collection, tubes were gently inverted 10 times to ensure thorough mixing of the additive with the blood. Incorrectly filled tubes or tubes with macroscopic clots were excluded. All samples were identified and transported to the university research laboratory while stored at room temperature. The median time between sample collection and analysis was 2:39 h (ranging from 1:30 to 4:54 h). A previously described semi-quantitative method of scoring, ranging from 1–4 (representing low to high difficulty in filling the tube), was used to evaluate sampling [34].

Hematological analyses

After being inverted 10 times, blood samples were analyzed using the in-house Procyte Dx Hematology Analyzer (IDEXX Laboratories, Inc., Westbrook, Maine 04092, USA) with a species-specific setting for pigs. Complete blood cell counts (CBCs) included red blood cell (RBC) count, hemoglobin (HGB), hematocrit (HCT), mean corpuscular volume (MCV), mean corpuscular hemoglobin (MCH), mean corpuscular hemoglobin concentration (MCHC), reticulocyte count (absolute count and percentages), RBC distribution width standard deviation (RDW-SD), RBC distribution width as a coefficient of variation (RDW-CV), white blood cell (WBC) count, and the leukocyte differential count (absolute count and percentages). All samples were analyzed in duplicates and the average value of the duplicates was used. Blood films from each EDTA blood sample were prepared, air-dried, stained with Hemacolor (Hemacolor® Rapid staining of blood smear, Merck KGaA, 64,271 Darmstadt, Germany), fixed and stored. Blood films were examined by a trained medical laboratory technician in a blinded manner. The number of single platelets and platelets in clumps were calculated in eight high power fields and an estimated error in the total platelet count was calculated as "number of platelets in clumps"/"total counted number of platelets" (Additional file 1). Data were extracted from the Procyte Dx Hematology Analyzer and loaded into Excel (MS office, version 2016, Microsoft Corp., USA).

To ensure the stability of the analyzer, quality control was performed daily according to the manufacturer’s instructions. The mean value, standard deviation (SD) and the coefficient of variation (CV) of the quality controls are shown in an additional file (Additional file 2).

Statistical analysis

Reference intervals were determined using the add-in software Analyze-It for statistical analyses in Microsoft excel (Analyze-It Version 3.0; Analyze-It Software, Leeds, UK). The data distribution of each hematological variable was assessed by visual inspection (q-q plots and histograms) and by the Shapiro–Wilks test with a significance level of 5%. Data showing a non-Gaussian distribution were transformed, if possible. Outliers were detected by the 1.5 interquartile range (IQR) method and removed [5, 31]. For Gaussian variables, the 2.5th, 50th and 97.5th percentiles with 90% confidence intervals (CIs) were estimated using parametric statistics (normal quantile) as recommended by the ASVCP for de novo determination of RIs in veterinary species [31, 35]. Variables with a non-Gaussian distribution were calculated non-parametrically (bootstrap quantile method) and the 2.5th, 50th and 97.5th percentiles with 90% confidence intervals were estimated.

Results

A total of 141 pigs were inspected. Four pigs were excluded due to lameness (1), coughing (1), abnormal lung sounds (1), or unsuccessful anesthesia (1). Four blood samples were excluded before analysis because of inadequate tube filling (3) or presence of macroscopic clots (1). Thus, 133 blood specimens were available for RI determination (Fig. 1). Outliers, sample sizes and RIs with 90% CIs for lower and upper limits are shown in Table 1. Baseline variables of all included pigs are presented in Table 2. The data distribution for hematological parameters is visualized in Additional file 3.

Table 1 Hematologic reference intervals for LYD pigs, 35–65 kg
Table 2 Weight, temperature, pulse, respiration and SpO2 of reference pigs, estimated age 3–4 months

A “platelet abnormal distribution” flag was generated by the analyzer in 32 of the blood specimens. The degree of platelet aggregation in these samples was compared with a random sample of specimens without a flag, by examining blood films from the specimens. No difference in percent estimated error in the total platelet count was observed between blood films with and without platelet flagging. Furthermore, no correlation was found between sampling difficulty and samples with a flagging of platelets (Additional file 1).

The platelet flagging effect on the hematological parameters was evaluated by comparing RIs calculated with and without blood specimens with a flag for abnormal distribution of platelets. For RBCs and derived parameters and for WBCs variables, no effect was observed. For platelets (PLT-O and PLT-I) and to a lesser extend platelet indices (PDW, PPV-O, P-LCR and PCT), an effect could be seen reflected by a lowering of the lower reference limit if specimens with an abnormal platelet distribution were included in the RIs. Based on this investigation, the flagged specimens were excluded in the RI determination of platelet count and platelet indices but included in the determination of the remaining RIs.

Discussion

The objective of this study was to establish hematologic reference values for commonly measured hematological parameters in healthy LYD pigs utilized for biomedical research or surgical training.

When we compared our findings to reference intervals of other porcine breeds such as the Norwegian grower pigs and juvenile Yorkshire pigs, slight variations were noticed [19, 25]. For instance, the RIs for red blood cells were RBC (5.10–7.00 × 106/µL), HGB (9.36–12.29 g/dL), and HCT (30.46–40.47%) whereas the RIs published for Norwegian grower pigs were (6.4–8.8 × 106/µL, 10.5–13.5 g/dL, and 0.34–0.44%, respectively) and for juvenile Yorkshire pigs (4.80–7.11 × 106/µL, 8.20–11.7 g/dL, and 25.38–38.77%, respectively). The differences highlight the importance of establishing reference intervals for the specific breed and underscores the fact that there are variations in hematological variables among pigs of different breeds and ages [9,10,11,12, 14,15,16,17,18,19,20,21,22,23,24,25, 27]. In this regard it is worth noticing that the LYD pigs in this study were females and 3–4 months old based on weight. This life stage is characterized by rapid growth and significant physiological changes. Blood volume increases and the intake of essential nutrients, such as iron, is vital [26]. Notably, the RI for HGB in our study were significantly higher compared to piglets not treated with iron (3.56–7.74 g/dL) [16]. This reflects the iron supplementation the pigs in our study received and is consistent with previous findings of lower erythroid values in younger pigs without iron supplementation [36].

Comparison of RIs for WBC also revealed differences [14,15,16,17]. We noticed that the reference limits for WBC reported for Danish sows (Landrace-Yorkshire) at mid-gestation (8.67–23.64 × 109/L) were lower compared to our findings. This finding highlights the importance of considering age and gestational status when interpreting hematological data [22]. Also, when comparing our results to small pig breeds, we noticed that these breeds had narrower RIs with lower limits, e.g., female miniature pigs (0–17.44 × 103/L) and female minipigs (8.90–13.40 × 109/L) [9, 13]. This may be due to genetic factors, but biosecurity and health status may also influence the results.

We thoroughly examined the health of the included pigs to ensure that the RIs generated were not inadvertently skewed by inclusion of sick animals [37]. WBC values in particular may vary considerably in the presence of some pathogens manifesting as inflammation and infection [37]. The two-step clinical examination included both observations at rest and during locomotion as well as temperature, respiratory and cardiovascular examinations. Hence, we are confident that we did not overlook clinical illness. We notice that some studies state that animals are deemed healthy upon appearance without further mentioning of clinical examinations. Other studies in particularly in pets describe a thorough examination process that also tests for common species-specific subclinical infections [34]. The animals in this study were part of a large national pathogen screening program and this further decreases the risk of including animals with subclinical disease.

Leukocytosis is also a common response to stress [26]. The stress associated with handling and restraint affects the leukogram [38, 39]. In this study, pigs were anesthetized during blood collection to minimize stress-related alterations in WBC parameters. Anesthesia itself may, however, also alter hematological parameters, thus there is no gold standard and one must always consider how the animals were handled during sampling [38].

We investigated female animals as this gender is used at the research facility. Gender influences RIs and must be kept in mind when interpreting these data. Sex hormones are e.g. known to influence erythropoiesis [40]. The animals in this study were, however, not sexually mature. It would be interesting to pursue this further and disclose if and how much difference there may be between genders at this life stage and whether it is necessary to divide RIs based on gender at such an early age. We notice that in 3-week-old Ontario nursing pigs representing both sexes, the reference interval is almost equivalent to our findings for WBC (93.0–136.0 g/L) [14,15,16,17]. Overall, when comparing our findings to other studies, the impact of age, breed, housing and husbandry, sexual maturity, gestation and disease on hematological variables must be considered.

A rigorous methodology was employed to ensure the accuracy of the generated RIs and avoid skewing and confounding factors. Pre-analytical factors such as the use of anticoagulants, sample collection and handling, and storage conditions can affect the integrity of blood samples [38, 41]. RIs were established using blood samples collected from the marginal auricular vein, as this site offers easy accessibility, is well-suited for catheterization without influencing preanalytical variability, and particularly advantageous for collecting small blood volumes. Proper needle selection is critical to maintain sample integrity and minimize preanalytical variability [42]. To ensure adequate blood flow and minimize shear stress, reduce the risk of hemolysis, platelet activation, and clot formation an 18-gauge needle was employed for blood collection in this study. Blood samples were collected in EDTA tubes according to the user manual for the dedicated hematology analyzer and advice from Idexx’ technical support. EDTA tubes effectively prevent clot formation by chelating calcium ions [41]. However, EDTA may induce platelet aggregation and potentially lead to pseudothrombocytopenia [41, 43,44,45,46,47,48,49,50]. Alternative tubes e.g., coated with citrate, theophylline, adenosine, and dipyridamole (CTAD) reduce platelet aggregation in feline samples and may offer similar benefits for porcine blood [34]. The use of CTAD tubes in the current hematology analyzer was strongly discouraged by Idexx. Observations from previous studies do however suggest that porcine plasma is hypercoagulable [51, 52]. Hence, it would be interesting to analyze porcine blood on an analyzer capable of analyzing blood collected in CTAD tubes. If this decreases the number of platelet flagging, it is worth considering if the ability to analyze CTAD tubes should be a prerequisite for hematological analyzers dedicated to analyses of porcine samples.

Hematological analyzers combine methods such as impedance and/or optical cell counting. Each method has its capabilities and limitations [53]. Impedance counters measure cell size and are affected by platelet aggregates. Optical cell counters utilize light scattering patterns that are less influenced by platelet aggregation but are, however, not immune to these errors [53]. The ProCyte Dx Haematology Analyzer used in this study combines laser flow cytometry, optical fluorescence, and laminar flow impedance. This combination provides more accurate separation between red blood cells and platelets and an enhanced WBC differential [54]. The analyzer software contains a “flagging system”, which indicates potential sources of errors in cellular identification. “Platelet abnormal distribution” was flagged in 32 out of 133 blood specimens. This flag indicates abnormal distribution of platelet size, shape, or number, or too few platelets available for accurate assessment. To investigate this further, we performed a microscopic evaluation of peripheral blood films as suggested in the Idexx Operators’ Guide [54]. We found no difference in percent estimated error in the total platelet count between blood films with and without platelet flagging. No trend was observed, and no correlation was found between sampling difficulty and samples with an abnormal distribution of platelets. Platelet aggregates can interfere with impedance counting by altering perceived cell size, leading to underestimation of platelet counts and a false increase in other cell types [53]. Platelet clumping has been reported to spuriously elevate leukocyte counts and influence specific leukocyte populations across species, e.g. eosinophils and neutrophils in dogs and basophils and eosinophils in cats [55,56,57]. Our study found no significant differences in erythrocyte or leukocyte values with and without abnormal platelet flagging, indicating that platelet aggregation specifically impacted platelet counts rather than other cell types. Recent advancements in automated platelet counting methods, based on fluorescent labeling and flow cytometry, provide a more accurate platelet count [58]. These technologies may represent the next step forward in veterinary hematology, potentially overcoming the challenges we experienced with platelet flagging. Nevertheless, our experience from this study highlights the importance of sampling collection techniques, and indeed the type of hematological analyzer used. There is however no doubt about the fact that the susceptibility to platelet aggregation in pigs is influenced by complex factors beyond sample handling and preparation. Future research should continue to explore this. Additionally, objective and standardizing methods for assessing platelet aggregation and investigating the behavior of porcine thrombocytes under various storage conditions will further enhance the accuracy and reliability of hematological assessments, ultimately improve the quality and applicability of the results.

Conclusions

Our study discloses differences in reference values of several hematological parameters for LYD pigs in comparison to published RIs for other pigs, highlighting the influence of pre-analytical conditions, laboratory measurement techniques, and factors such as age, breed, gestation, and health status on hematological parameters. The findings emphasize the need for laboratories to establish laboratory-specific reference values for hematological parameters in pigs of different breeds and ages, adhering to stated pre-analytical procedures and using the available hematological analyzer. While our results may not perfectly translate to every pig breed, they offer a robust general reference that is useful to improve health assessments and physiological monitoring in both biomedical and veterinary contexts. Additionally, the LYD-specific RIs generated in this study serve as a vital tool for post-operative welfare monitoring and accurate interpretation of experimental outcomes. This step represents a significant 3R advancement toward refinement of experimental protocols and ethical use of animals in research. By providing these physiological standards, our work supports the broader aim of improving both scientific rigor and animal welfare in translational research and may find relevance in several settings such as disease modelling and xenotransplantation.

Availability of data and materials

The datasets used and/or analyzed during the current study are available from the corresponding author on reasonable request.

References

  1. Gutierrez K, Dicks N, Glanzner WG, Agellon LB, Bordignon V. Efficacy of the porcine species in biomedical research. Front Genet. 2015;6:293.

    Article  PubMed  PubMed Central  Google Scholar 

  2. European Commission. Animals Used for Scientific Purposes: EU Statistical Reports on the Use of Animals for Scientific Purposes. 2024. https://environment.ec.europa.eu/topics/chemicals/animals-science_en. Accessed 25 Feb 2024.

  3. Smith AC, Swindle MM. Preparation of swine for the laboratory. Ilar j. 2006;47:358–63.

    Article  PubMed  CAS  Google Scholar 

  4. Swindle M. Swine in the Laboratory: Surgery, Anesthesia, Imaging and Experimental Techniques, 3rd Edition, Boca Raton: CRC Press, 2015.

  5. Horn PS, Pesce AJ. Reference intervals: an update. Clin Chim Acta. 2003;334:5–23.

    Article  PubMed  CAS  Google Scholar 

  6. Geffré A, Friedrichs K, Harr K, Concordet D, Trumel C, Braun JP. Reference values: a review. Vet Clin Pathol. 2009;38:288–98.

    Article  PubMed  Google Scholar 

  7. Ministry of Food, Agriculture and Fisheries of Denmark. The Animal Experiments Inspectorate. Experimental animal use 2022. 2024. https://dyreforsoegstilsynet.dk/indberetning/statistik/2022. Accessed 26 Jun 2024.

  8. Danish Agriculture & Food Council. Pigmeat Statistics 2022. 2024. https://agricultureandfood.dk/statistics/annual-statistics/pigmeat-statistics-2022/. Accessed 26 Jun 2024.

  9. Yeom SC, Cho SY, Park CG, Lee WJ. Analysis of reference interval and age-related changes in serum biochemistry and hematology in the specific pathogen free miniature pig. Lab Anim Res. 2012;28:245–53.

    Article  PubMed  PubMed Central  Google Scholar 

  10. Kawaguchi H, Yamada T, Miura N, Takahashi Y, Yoshikawa T, Izumi H, et al. Reference values of hematological and biochemical parameters for the world smallest microminipigs. J Vet Med Sci. 2012;74:933–6.

    Article  PubMed  Google Scholar 

  11. Chen Y, Qin S, Ding Y, Li S, Yang G, Zhang J, et al. Reference values of biochemical and hematological parameters for Guizhou minipigs. Exp Biol Med (Maywood). 2011;236:477–82.

    Article  PubMed  CAS  Google Scholar 

  12. Rispat G, Slaoui M, Weber D, Salemink P, Berthoux C, Shrivastava R. Haematological and plasma biochemical values for healthy Yucatan micropigs. Lab Anim. 1993;27:368–73.

    Article  PubMed  CAS  Google Scholar 

  13. Ellegaard L, Jorgensen KD, Klastrup S, Hansen AK, Svendsen O. Haematologic and Clinical Chemical values in 3 and 6 months old Göttingen minipigs. Scand J Lab Anim Sci. 1995;22:1.

    Google Scholar 

  14. Li C, Wang F, Li R, Ishfaq M, Chen H, Liu F, et al. Hematologic and biochemical reference intervals for 1-month-old specific-pathogen-free Landrace pigs. Vet Clin Pathol. 2021;50:76–80.

    Article  PubMed  CAS  Google Scholar 

  15. Li R, Wang F, Zhang Y, Li C, Xia C, Chen H, et al. Comparison of hematologic and biochemical reference values in specific-pathogen-free 1-month-old Yorkshire pigs and Yorkshire-Landrace crossbred pigs. Can J Vet Res. 2019;83:285–90.

    PubMed  PubMed Central  CAS  Google Scholar 

  16. Ventrella D, Dondi F, Barone F, Serafini F, Elmi A, Giunti M, et al. The biomedical piglet: establishing reference intervals for haematology and clinical chemistry parameters of two age groups with and without iron supplementation. BMC Vet Res. 2017;13:23.

    Article  PubMed  PubMed Central  Google Scholar 

  17. Perri AM, O’Sullivan TL, Harding JC, Wood RD, Friendship RM. Hematology and biochemistry reference intervals for Ontario commercial nursing pigs close to the time of weaning. Can Vet J. 2017;58:371–6.

    PubMed  PubMed Central  CAS  Google Scholar 

  18. Cooper CA, Moraes LE, Murray JD, Owens SD. Hematologic and biochemical reference intervals for specific pathogen free 6-week-old Hampshire-Yorkshire crossbred pigs. J f Anim Sci Biotechnol. 2014;5:5.

    Article  Google Scholar 

  19. Klem TB, Bleken E, Morberg H, Thoresen SI, Framstad T. Hematologic and biochemical reference intervals for Norwegian crossbreed grower pigs. Vet Clin Pathol. 2010;39:221–6.

    Article  PubMed  Google Scholar 

  20. Brockus CW, Mahaffey EA, Bush SE, KruppDespain W. Hematologic and serum biochemical reference intervals for Vietnamese potbellied pigs (Sus scrofa). Comp Clin Path. 2005;13:162–5.

    Article  Google Scholar 

  21. Faustini M, Bronzo V, Maffeo G, Russo V, Munari E, Vigo D. Reference intervals and age-related changes for platelet count, mean platelet volume and plateletcrit in healthy pre-weaning piglets in Italy. J Vet Med Ser A. 2003;50:466–9.

    Article  CAS  Google Scholar 

  22. Faustini M, Munari E, Colombani C, Russo V, Maffeo G, Vigo D. Haematology and plasma biochemistry of Stamboek pre-pubertal gilts in Italy: reference values. J Vet Med A Physiol Pathol Clin Med. 2000;47:525–32.

    Article  PubMed  CAS  Google Scholar 

  23. Friendship RM, Lumsden JH, McMillan I, Wilson MR. Hematology and biochemistry reference values for Ontario swine. Can J Comp Med. 1984;48:390–3.

    PubMed  PubMed Central  CAS  Google Scholar 

  24. Egeli AK, Framstad T, Morberg H. Clinical biochemistry, haematology and body weight in piglets. Acta Vet Scand. 1998;39:381–93.

    Article  PubMed  PubMed Central  CAS  Google Scholar 

  25. Dimitrakakis N, Waterhouse A, Lightbown S, Leslie DC, Jiang A, Bolgen DE, et al. Biochemical and Hematologic Reference Intervals for Anesthetized, Female, Juvenile Yorkshire Swine. J Am Assoc Lab Anim Sci. 2022;61:21–30.

    Article  PubMed  PubMed Central  Google Scholar 

  26. Thorn CE, Bowman AS, Eckersall D. Hematology of Pigs. Schalm's Veterinary Hematology; https://doiorg.publicaciones.saludcastillayleon.es/10.1002/9781119500537.ch1132022. p. 1019–25.

  27. Bhattarai S, Framstad T, Nielsen JP. Hematologic reference intervals of Danish sows at mid-gestation. Acta Vet Scand. 2019;61:16.

    Article  PubMed  PubMed Central  Google Scholar 

  28. CLSI and IFCC. C28–A3 document. Defining, establishing, and verifying reference intervals in the clinical laboratory: approved guideline-third edition. 2008;28:1–76.

    Google Scholar 

  29. Solberg HE. Approved recommendation (1987) on the theory of reference values. Part 5. Statistical treatment of collected reference values Determination of reference limits. Clin Chim Acta. 1987;170:S13-S32.

  30. Friedrichs KR, Harr KE, Freeman KP, Szladovits B, Walton RM, Barnhart KF, et al. ASVCP reference interval guidelines: determination of de novo reference intervals in veterinary species and other related topics. Vet Clin Pathol. 2012;41:441–53.

    Article  PubMed  Google Scholar 

  31. American Society for Veterinary Clinical Pathology. Guidelines for the Determination of Reference Intervals in Veterinary Species. 2024. https://www.asvcp.org/page/QALS_Guidelines. Accessed 27 May 2021.

  32. SPF-sus. SPF-Health Regulations. 2025. https://spfsus.dk/. Accessed 12 Feb 2025.

  33. Thomsen AF, Kousholt BS. Transition of farm pigs to research pigs using a designated checklist followed by initiation of clicker training - a refinement initiative. J Vis Exp. 2021. https://doiorg.publicaciones.saludcastillayleon.es/10.3791/62099.

    Article  PubMed  Google Scholar 

  34. Granat F, Geffré A, Bourgès-Abella N, Mortier J, Théron M-L, Fauchon E, et al. Feline reference intervals for the Sysmex XT-2000iV and the ProCyte DX haematology analysers in EDTA and CTAD blood specimens. J Feline Med Surg. 2014;16:473–82.

    Article  PubMed  Google Scholar 

  35. Linnet K. Nonparametric estimation of reference intervals by simple and bootstrap-based procedures. Clin Chem. 2000;46:867–9.

    Article  PubMed  CAS  Google Scholar 

  36. Czech A, Grela E, Klebaniuk R, Katarzyna O, Samolińska W. Polish crossbred pigs’ blood haematological parameters depending on their age and physiological state. Ann Warsaw Univ Life Sci. 2018;56:185–95.

    Article  Google Scholar 

  37. Golinar Oven I, Nemec Svete A, Hajdinjak M, Plut J, Štukelj M. Haematological profiles of pigs of different age in relation to the presence or absence of porcine reproductive and respiratory virus, porcine circovirus type 2 and hepatitis E virus. Ital J Anim Sci. 2022;21:1287–96.

    Article  CAS  Google Scholar 

  38. Humann-Ziehank E, Ganter M. Pre-analytical factors affecting the results of laboratory blood analyses in farm animal veterinary diagnostics. Animal. 2012;6:1115–23.

    Article  PubMed  CAS  Google Scholar 

  39. Rosochacki SJ, Piekarzewska AB, Połoszynowicz J, Sakowski T. The influence of restraint immobilization stress on the concentration qf bioamines and cortisol in plasma of Pietrain and Duroc pigs. J Vet Med A Physiol Pathol Clin Med. 2000;47:231–42.

    Article  PubMed  CAS  Google Scholar 

  40. Warren AM, Grossmann M. Haematological actions of androgens. Best Pract Res Clin Endocrinol Metab. 2022;36: 101653.

    Article  PubMed  CAS  Google Scholar 

  41. Banfi G, Salvagno GL, Lippi G. The role of ethylenediamine tetraacetic acid (EDTA) as in vitro anticoagulant for diagnostic purposes. Clin Chem Lab Med. 2007;45:565–76.

    Article  PubMed  CAS  Google Scholar 

  42. Lippi G, Salvagno GL, Montagnana M, Poli G, Guidi GC. Influence of the needle bore size on platelet count and routine coagulation testing. Blood Coagul Fibrinolysis. 2006;17:557–61.

    Article  PubMed  Google Scholar 

  43. Bizzaro N. EDTA-dependent pseudothrombocytopenia: A clinical and epidemiological study of 112 cases, with 10-year follow-up. Am J Hematol. 1995;50:103–9.

    Article  PubMed  CAS  Google Scholar 

  44. Casonato A, Bertomoro A, Pontara E, Dannhauser D, Lazzaro AR, Girolami A. EDTA dependent pseudothrombocytopenia caused by antibodies against the cytoadhesive receptor of platelet gpIIB-IIIA. J Clin Pathol. 1994;47:625–30.

    Article  PubMed  PubMed Central  CAS  Google Scholar 

  45. Lippi G, Plebani M. EDTA-dependent pseudothrombocytopenia: further insights and recommendations for prevention of a clinically threatening artifact. Clin Chem Lab Med. 2012;50:1281–5.

    Article  PubMed  CAS  Google Scholar 

  46. Nagler M, Keller P, Siegrist D, Alberio L. A case of EDTA-dependent pseudothrombocytopenia: simple recognition of an underdiagnosed and misleading phenomenon. BMC Clin Pathol. 2014;14:19.

    Article  PubMed  PubMed Central  Google Scholar 

  47. Hinchcliff KW, Kociba GJ, Mitten LA. Diagnosis of EDTA-dependent pseudothrombocytopenia in a horse. J Am Vet Med Assoc. 1993;203:1715–6.

    Article  PubMed  CAS  Google Scholar 

  48. Norman EJ, Barron RCJ, Nash AS, Clampitt RB. Evaluation of a citrate-based anticoagulant with platelet inhibitory activity for feline blood cell counts. Vet Clin Pathol. 2001;30:124–32.

    Article  PubMed  Google Scholar 

  49. Wills TB, Wardrop KJ. Pseudothrombocytopenia secondary to the effects of EDTA in a dog. J Am Anim Hosp Assoc. 2008;44:95–7.

    Article  PubMed  Google Scholar 

  50. Erkens T, Van den Sande L, Witters J, Verbraeken F, Looszova A, Feyen B. Effect of time and temperature on anticoagulant-dependent pseudothrombocytopenia in Göttingen minipigs. Vet Clin Pathol. 2017;46:416–21.

    Article  PubMed  Google Scholar 

  51. Roussi J, André P, Samama M, Pignaud G, Bonneau M, Laporte A, et al. Platelet functions and haemostasis parameters in pigs: Absence of side effects of a procedure of general anaesthesia. Thromb Res. 1996;81:297–305.

    Article  PubMed  CAS  Google Scholar 

  52. Alstrup A, Kornerup Hansen A, Jespersen J, Marckmann P, Bladbjerg E-M. The pig as a model in blood coagulation and fibrinolysis research. Scand J Lab Anim Sci. 1999;26:214–24.

    Google Scholar 

  53. DeNicola DB. Advances in Hematology Analyzers. Top Companion Anim Med. 2011;26:52–61.

    Article  PubMed  Google Scholar 

  54. IDEXX Hematology. ProCyte Dx Operator’s Guide 2021. 2025. https://www.idexx.com/en/veterinary/analyzers/hematology/hematology-resources/. Accessed 11 Feb 2025.

  55. Zandecki M, Genevieve F, Gerard J, Godon A. Spurious counts and spurious results on haematology analysers: a review Part I: platelets. Int J Lab Hematol. 2007;29:4–20.

    Article  PubMed  CAS  Google Scholar 

  56. Zandecki M, Genevieve F, Gerard J, Godon A. Spurious counts and spurious results on haematology analysers: a review. Part II: white blood cells, red blood cells, haemoglobin, red cell indices and reticulocytes. Int J Lab Hematol. 2007;29:21–41.

    Article  PubMed  CAS  Google Scholar 

  57. IDEXX Hematology. Interpreting dot plots. 2024. https://www.idexx.com/en/veterinary/analyzers/hematology/hematology-resources/dot-plots/. Accessed 8 Aug 2024.

  58. Wada A, Takagi Y, Kono M, Morikawa T. Accuracy of a New Platelet Count System (PLT-F) Depends on the Staining Property of Its Reagents. PLoS ONE. 2015;10: e0141311.

    Article  PubMed  PubMed Central  Google Scholar 

Download references

Acknowledgements

The authors sincerely thank Frank Skov Jensen, Department of Clinical Biochemistry, Aarhus University Hospital, Aarhus, Denmark, for examining blood films and calculating the percent estimated error in the total platelet count.

Funding

This study was funded by a grant from Anna & Dagny Hjerrilds Foundation at Aarhus University. The funder had no role in study design, data collection and analyses, decision to publish or preparation of the manuscript.

Author information

Authors and Affiliations

Authors

Contributions

K.F.P. and B.S.K. designed the study and collected samples. K.F.P. and A.W.L. processed and analyzed the samples and data. K.F.P. and B.S.K. drafted the manuscript. All authors have read and accepted the final version of the manuscript.

Corresponding author

Correspondence to Kirstine Færgemand Præstegaard.

Ethics declarations

Ethics approval and consent to participate

The animals were handled according to high ethical standards and national legislation. The study was approved by The Animal Experimental Council in Denmark (license number 2021–15-0201–00966.) and performed in accordance with the guidelines by the American Society of Veterinary Clinical Pathology.

Consent for publication

Not applicable.

Prior publication

Data have not been published previously.

Competing interests

The authors declare that they have no competing interests.

Additional information

Publisher's Note

Springer Nature remains neutral with regard to jurisdictional claims in published maps and institutional affiliations.

Supplementary Information

Additional file 1.

Estimated error (%) in the total platelet count. The number of single platelets and platelets in clumps were calculated in eight high power fields and an estimated error in the total platelet count was calculated as "number of platelets in clumps"/"total counted number of platelets".

Additional file 2.

Quality controls. The mean value, standard deviation (SD) and the coefficient of variation (CV) of the quality controls.

Additional file 3.

Scatter plots. The data distribution for hematological parameters.

Rights and permissions

Open Access This article is licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons licence, and indicate if changes were made. The images or other third party material in this article are included in the article's Creative Commons licence, unless indicated otherwise in a credit line to the material. If material is not included in the article's Creative Commons licence and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this licence, visit http://creativecommons.org/licenses/by/4.0/. The Creative Commons Public Domain Dedication waiver (http://creativecommons.org/publicdomain/zero/1.0/) applies to the data made available in this article, unless otherwise stated in a credit line to the data.

Reprints and permissions

About this article

Check for updates. Verify currency and authenticity via CrossMark

Cite this article

Præstegaard, K.F., Winther-Larsen, A. & Kousholt, B.S. Hematological reference intervals for Danish crossbred Landrace Yorkshire Duroc (LYD) pigs used in biomedical research. Acta Vet Scand 67, 11 (2025). https://doiorg.publicaciones.saludcastillayleon.es/10.1186/s13028-025-00798-6

Download citation

  • Received:

  • Accepted:

  • Published:

  • DOI: https://doiorg.publicaciones.saludcastillayleon.es/10.1186/s13028-025-00798-6

Keywords